PE-SI-009 no longer treats ESP32 CHIP_PU/EN RC as a USB series R.
USB without a library Z number stays PE-SI-010 measurement-only.
Pintable skill 1.13.0 requires net_class on SI kinds (usb2/usb3/MDI/RGMII/DDR3).
Package/pinout/ratings mismatches, SPOF as REVIEW, EMI only with a
datasheet quote, and Tj from copper+vias+θJA when every parameter exists.
Re-extract SI layout_rules from 1.12.0; ImpedenceFinder license stays UNKNOWN.
Each layout_rules SI requirement (diff/SE Z, skew, max length, spacing,
ref plane, vias, layer, return, series R) is one PASS/FAIL/MARGIN finding
with FACT and REQUIREMENT. USB/HDMI/PCIe/ETH/LVDS/DDR only; I2C GPIO CC
and analog REGN are skipped. No invented 90 Ω.
ERROR stays only for RULE+MANDATORY. Hierarchy walks component→pin→net→block.
Derating is PASS/MARGIN/RISK from Vop/Vrated. Timing and PI skip without numbers.
ESD and HS return path are REVIEW, not RULE ERROR.
FACT, REQUIREMENT, and INFERENCE are separate fields; datasheet provenance
lives in the rule DB so Recommended cannot stay ERROR; LLM output is REVIEW.
Designer decisions persist across rescans. Schematic and PCB share one library
and the same finding object in the report UI.
PCB AI skips a second PDF exam (pintable cache, pdf_path=None) and the report
gains a PCB exam section plus power-trace, thermal, via, Kelvin, and GND-stitch
checks grounded in board geometry and extracted specs.
Documents a parallel MODE=pcb exam job (inventory + datasheet-gated
checks) that reuses placement_check, si_check, and the placement job
pattern. Parks F2 packing/export.