michele 1b3529501f Ship remaining PCB plan slices: BOM chain, SPOF, EMI FACT, gated Tj.
Package/pinout/ratings mismatches, SPOF as REVIEW, EMI only with a
datasheet quote, and Tj from copper+vias+θJA when every parameter exists.
Re-extract SI layout_rules from 1.12.0; ImpedenceFinder license stays UNKNOWN.
2026-09-20 12:29:27 +02:00

6.3 KiB
Raw Blame History

Piano — PCB review (esame geometria + stesso motore finding)

Specifica finding: motore-finding.md. Schema e PCB usano lo stesso oggetto. Questo file è il job layout.

Non è un auto-placer. PCB-only = geometria (mm, width, copper, via, pour, return stitch, pad-net). Validazione netlist / mux / LED resta schema.

Contratto:

Schema PCB review Placement F2 (fuori)
Promessa Netlist vs libreria datasheet Layout vs libreria + geometria xy nuovi
Motore finding FACT / REQUIREMENT / INFERENCE uguale
Deep exam PDF Una voltalibrary/extracted Consuma cache, pdf_path=None
Job MODE=run MODE=pcb MODE=placement
Output report.json pcb_report.json (merge in GET /report) pack json

Senza .kicad_pcb il progetto è schema-completo. Il report schema non si riempie di PE-PLC/PE-SI.


Motore (schema + PCB)

Vedi motore-finding.md. Invarianti:

  1. Non mescolare FACT / REQUIREMENT / INFERENCE.
  2. Provenance MANDATORY | RECOMMENDED | TYPICAL | EXAMPLE nel rule DB. Recommended ≠ ERROR.
  3. Classi RULE | RISK | REVIEW | INFO. LLM = REVIEW, mai RULE.
  4. decisions.json + fingerprint: rescan non ri-naga (PSEL low intenzionale, ecc.).
  5. status, confidence, evidence_status indipendenti.
  6. Evidenza insufficiente → lo si dice, niente 1 oz / 10 °C / 50 Ω / IEC inventati.
  7. Oggetto riproducibile: facts, requirement, source, calculation, assumptions, confidence, severity, action.

UI report (schema e layout): stessa FindingCard — Fact / Requirement / Inference, badge classe e provenance.

Libreria: library/extracted/{safe_mpn}.json extracted/ progetto. PDF in library/datasheets/blobs/.


Job PCB (invariato nello stack)

                    ┌─ MODE=run        → status           → report.json
  Project files  ───┼─ MODE=placement  → placement_status → placement_plan.json
                    └─ MODE=pcb        → pcb_status       → pcb_report.json

Stages: ensure_graphparse_pcbclassifyinventorychecksai_review (layout vs library, no PDF) → write_report.

Mutex vs analisi e vs placement. SSE pcb_*. IDs PCB-{ref}-{001}. KiCad /net vs net schema: PE-LAY-003 una volta, non per-pad (kicad_nets_match).

Check PCB (geometria) — gated

ID Gate
PE-LAY-001…003 pad/ref/hierarchy nets
PE-PLC-001…004 layout_rules numerici
PE-SI-001 length_match mm on USB/HDMI/PCIe/ETH/LVDS/DDR nets (not I2C/GPIO/CC)
PE-SI-002 ImpedenceFinder Zavg/min/max vs impedance window
PE-SI-003…009 max length, spacing, ref plane, vias, return, series R — each a datasheet number
PE-SI-010 HS bus measured, library has no SI FACT (not 90 Ω folklore)
PE-PWR-001 I_load + width; IPC solo con thickness e Tjmax
PE-DRT-001 Vop e Vrated, Vop > Vr → RULE ERROR
PE-DRT-002 0.8 < Vop/Vr ≤ 1 → RISK MARGIN
PE-DRT-003 Vop/Vr ≤ 0.8 → PASS summary INFO
PE-HIER-001 pin IC senza net
PE-TIM-001/002 RC / strap solo con numeri
PE-PI-001/002 local vs bulk; mm solo da layout_rules
PE-ESD-001 / PE-RET-001 REVIEW unless mandatory FACT
PE-VIA-001 via count + I_load (INFO, no tabella inventata)
PE-THM-001 P=I_load×drop, courtyard senza pour/via
PE-THM-002 Tj=Ta+P·θJA solo con P, θJA, area rame, conteggio via
PE-BOM-010…014 package / pinout / V / T / I quando BOM, PCB e datasheet hanno i numeri
PE-SPOF-001 un regolatore (o un XTAL condiviso) — REVIEW
PE-EMI-001 filtro EMI solo se layout_rules cita choke/ferrite/shield
PE-KEL-001 sense/Kelvin pintable + ≥2 altri sul net
PE-STCH-001 pour GND + segnale senza via GND nel bbox
Creepage skip senza numero datasheet/IEC
Crystal keepout PE-PLC-004 se kind=keepout

AI PCB: skip IC senza pintable (run schematic review first).


Fasi

A — shipped: oggetto finding condiviso, clamp provenance/class (ERROR solo RULE+MANDATORY), decisions, UI, libreria unica, geometria gated, net-slash, Action on card, geometria in contesto AI.

B — questa slice (shipped, gated):

ID Cosa Gate
Gerarchia hierarchy.json component→pin→net→block grafo (+ domains se classify)
PE-HIER-001 pin IC senza net FACT net=''
PE-DRT-001/002/003 RISK / MARGIN / PASS Vop e Vrated; niente % dielettrico inventato
PE-TIM-001/002 RC reset / strap R, C e t_reset o Vih/Vil numerici
PE-PI-001/002 local vs bulk, I se noto cap valorizzati; distanza solo con max_distance_mm
PE-ESD-001 ESD connettore/USB REVIEW se manca parte ESD
PE-RET-001 return HS senza via GND REVIEW, non ERROR

B — SI (shipped, gated): ImpedenceFinder is in the checks, not only the impedance tab dump. Each datasheet SI requirement is one finding: PASS / FAIL / MARGIN + FACT / REQUIREMENT / source. Buses: USB D+/D, HDMI, PCIe, Ethernet, LVDS, DDR. Skip I2C, GPIO, EN, analog REGN, USB CC (not 90 Ω pairs). No invented 50/90 Ω.

Emmaforo USB verdict: if library has e.g. 90 Ω ±10% (8199), Zavg ~88 Ω PASS on average and MARGIN/FAIL if min (~46 Ω) is outside the window; ~2.5 mm intra-pair skew FAIL only when length_match mm exists and 2.5 > limit. Without library Z, PE-SI-010 INFO (insufficient) — not a 90 Ω ERROR.

B — still missing (true leftovers):

Gap Why it stays out
Thermal FEM / energy PE-THM-002 is Tj=Ta+P·θJA with measured copper/vias; no spreading/FEM
CPWG / OpenEMS Field-solver export excluded from the ImpedenceFinder vendor snapshot
ImpedenceFinder license Upstream has no LICENSE (UNKNOWN). Not invented in-tree. See vendor/impedancefinder/SOURCE.md
Auto-place / pcbnew write-back Fase C
PinScope identity / TOS Other worker

Shipped this close-out: BOM↔PCB↔datasheet (PE-BOM-010014); SPOF REVIEW; EMI with datasheet FACT; gated θJA Tj; SI re-extract when library layout_rules lack SI kinds (model_version 1.12.0, si_extract_needed.json).

C — fuori: auto-place, write-back pcbnew, unire i job, sshd/keys, PinScope identity/fork.

Deploy: ssh periscope + /root/periscope/scripts/update-periscope.sh.