"""Build a capacitor voltage derating table from the design graph. No AI — pure computation.""" from __future__ import annotations import re from backend.pinscopex.models import ComponentType, DesignGraph, NetType from backend.pinscopex.utils import natural_sort_key # Dielectric strings that indicate ceramic capacitors _CERAMIC_DIELECTRICS = {"X7R", "X5R", "C0G", "NP0", "Y5V", "X7S", "X6S", "X8R", "C0G (NP0)"} def _parse_voltage_rating(s: str | None) -> float | None: """Extract numeric voltage from a rating string like '16V', '25V', '2.5V'.""" if not s: return None m = re.match(r"([\d.]+)", s) return float(m.group(1)) if m else None def _dielectric_category(component_subtype: str | None, dielectric: str | None) -> str | None: """Map component subtype / dielectric to a derating category.""" if component_subtype: low = component_subtype.lower() if "tantalum" in low: return "tantalum" if "electrolytic" in low: return "electrolytic" if "ceramic" in low: return "ceramic" if dielectric: upper = dielectric.upper().strip() if upper in _CERAMIC_DIELECTRICS or any(d in upper for d in _CERAMIC_DIELECTRICS): return "ceramic" low = dielectric.lower() if "tantalum" in low or low == "ta": return "tantalum" if "electrolytic" in low or low == "al": return "electrolytic" # Default to ceramic (most common) return "ceramic" def build_derating_table(graph: DesignGraph) -> list[dict]: """Build a capacitor voltage derating table from the design graph. For each capacitor, determines: - Rated voltage (from specs) - Operating voltage (from connected net voltages) - Dielectric category (ceramic / tantalum / electrolytic) Returns a sorted list of dicts, one per capacitor designator. """ rows: list[dict] = [] for comp in graph.components.values(): if comp.component_type != ComponentType.CAPACITOR: continue # Rated voltage from specs rated_v: float | None = None value_fmt: str | None = None dielectric: str | None = None if comp.specs and hasattr(comp.specs, "voltage_rating_v"): rated_v = _parse_voltage_rating(comp.specs.voltage_rating_v) value_fmt = getattr(comp.specs, "value_formatted", None) dielectric = getattr(comp.specs, "dielectric", None) # Operating voltage: max non-zero voltage among connected nets op_voltage: float | None = None op_source: str | None = None for net_name in comp.pins.values(): net = graph.nets.get(net_name) if net and net.voltage is not None and net.voltage > 0: if op_voltage is None or net.voltage > op_voltage: op_voltage = net.voltage op_source = net_name # Determine net+ (highest voltage) and net- (ground / lowest voltage). # Deduplicate net names (multi-pin caps may connect twice to same net). seen: set[str] = set() connected: list[tuple[str, float | None, NetType | None]] = [] for net_name in comp.pins.values(): if net_name in seen: continue seen.add(net_name) net = graph.nets.get(net_name) v = net.voltage if net else None nt = net.net_type if net else None connected.append((net_name, v, nt)) net_plus: str | None = None net_minus: str | None = None if len(connected) == 1: # Single-net cap (both pins on same net) — show as net+ net_plus = connected[0][0] elif len(connected) >= 2: # Sort: ground first, then ascending by voltage (None < any number) by_v = sorted(connected, key=lambda c: ( c[2] != NetType.GROUND, # ground nets first c[1] is not None, # None before numbers c[1] or 0, # ascending voltage )) net_minus = by_v[0][0] net_plus = by_v[-1][0] rows.append({ "designator": comp.reference, "mpn": comp.mpn, "value_formatted": value_fmt, "rated_voltage_v": rated_v, "operating_voltage_v": op_voltage, "operating_voltage_source": op_source, "net_plus": net_plus, "net_minus": net_minus, "dielectric_category": _dielectric_category(comp.component_subtype, dielectric), }) rows.sort(key=lambda r: natural_sort_key(r["designator"])) return rows