michele bee6369c1d Replace findings list with a tree; filter ESD/PI false positives.
PE-ESD-001 only on J* connector–IC nets (skip NC, unconnected, VSYS/GND/3V3).
PE-PI-001 treats any capacitor on the rail, including KiCad slash prefixes, as
decoupling. Sort findings ERROR then WARNING then INFO, then RULE/RISK/REVIEW/INFO.
Report sidebar is a collapsed expand-on-click tree instead of an all-open list.
GET /report and complete_findings fail-soft and sort the same way.
2026-09-20 10:03:50 +02:00
michele 342792df2d Ship Fase B slices: hierarchy, derating bands, timing, PI, ESD/return.
ERROR stays only for RULE+MANDATORY. Hierarchy walks component→pin→net→block.
Derating is PASS/MARGIN/RISK from Vop/Vrated. Timing and PI skip without numbers.
ESD and HS return path are REVIEW, not RULE ERROR.
2026-09-20 09:35:04 +02:00
michele f63c1c3411 Tighten PCB findings: actions, stitch gating, real copper.
Fill action on every finding and show it in the report. Stitch/return only
on large HS/power nets. Parse stackup thickness, arcs, and vias from the
board. IC courtyard pad copper is not PE-PLC-004 RULE. Recommended RC/cap
stay REVIEW.
2026-09-20 08:58:54 +02:00
michele dc65e96a22 Apply the finding engine to schematic and PCB reviews.
FACT, REQUIREMENT, and INFERENCE are separate fields; datasheet provenance
lives in the rule DB so Recommended cannot stay ERROR; LLM output is REVIEW.
Designer decisions persist across rescans. Schematic and PCB share one library
and the same finding object in the report UI.
2026-09-20 08:38:59 +02:00