Treat KiCad Value/PNM as the IC MPN when the MPN column is empty.
Those 13 U* were in the BOM (TPS22965, TPD2E007, TMP117, …) but never entered ic_mpns, so review skipped them as missing PDFs. Also try the BOM Datasheet URL first. Co-authored-by: Cursor <cursoragent@cursor.com>
This commit is contained in:
@@ -0,0 +1,31 @@
|
||||
"""KiCad BOM: Value/PNM as MPN when Manufacturer Part Number is empty."""
|
||||
|
||||
from pathlib import Path
|
||||
|
||||
from backend.pinscopex.parsers import parse_bom
|
||||
|
||||
|
||||
def test_parse_bom_uses_value_for_ic_when_mpn_column_empty(tmp_path: Path):
|
||||
csv = tmp_path / "bom.csv"
|
||||
csv.write_text(
|
||||
"Reference,Qty,Value,DNP,Footprint,Datasheet,PNM\n"
|
||||
"U1,1,TPS22965DSGR,,SON-8,,\n"
|
||||
'"U9,U13",5,TPD2E007DCKR,,SOT-23,,\n'
|
||||
"C1,1,100nF,,0805,,\n"
|
||||
)
|
||||
bom = parse_bom(csv, mpn_col="Manufacturer Part Number")
|
||||
assert bom["U1"]["mpn"] == "TPS22965DSGR"
|
||||
assert bom["U9"]["mpn"] == "TPD2E007DCKR"
|
||||
assert bom["U13"]["mpn"] == "TPD2E007DCKR"
|
||||
assert bom["C1"]["mpn"] is None
|
||||
|
||||
|
||||
def test_parse_bom_keeps_pnm_and_datasheet_url(tmp_path: Path):
|
||||
csv = tmp_path / "bom.csv"
|
||||
csv.write_text(
|
||||
"Reference,Value,PNM,Datasheet\n"
|
||||
"U31,TMP117,TMP117NAIDRVR,https://www.ti.com/lit/ds/symlink/tmp117.pdf\n"
|
||||
)
|
||||
bom = parse_bom(csv, mpn_col="Manufacturer Part Number")
|
||||
assert bom["U31"]["mpn"] == "TMP117NAIDRVR"
|
||||
assert bom["U31"]["datasheet_url"].endswith("tmp117.pdf")
|
||||
Reference in New Issue