Fix KiCad .kicad_sch power/label net merging.
Disconnected GND power flags were named GND_/GND__/… so the reviewer flagged swapped rails and floating pins on correctly wired designs. Co-authored-by: Cursor <cursoragent@cursor.com>
This commit is contained in:
@@ -2,6 +2,14 @@
|
||||
|
||||
What's new in Pinscope.
|
||||
|
||||
## 2.26.4 — 2026-09-11 — KiCad power nets merge
|
||||
|
||||
`.kicad_sch` connectivity treated every `GND` power flag as its own island (`GND_`, `GND__`…), so the reviewer invented swapped rails and floating pins on good designs.
|
||||
|
||||
- [Fixed] Same-name power symbols and global/local labels merge within a sheet (KiCad semantics).
|
||||
- [Fixed] Pins sitting mid-wire attach to that net; `mirror x`/`y` handled correctly.
|
||||
- [Test] Disconnected GND flags, local labels, mid-segment wire.
|
||||
|
||||
## 2.26.3 — 2026-09-11 — KiCad project zip upload
|
||||
|
||||
One zip (or every `.kicad_sch`) covers hierarchical sheets. If the zip has `bom.csv` and `.kicad_pcb`, those are taken too. Pipeline re-reads companions from storage.
|
||||
|
||||