Run ImpedenceFinder Z0 on routed signal nets during project analysis.

Pipeline samples PCB traces when stackup εr/h is present; power/ground are skipped. Named nets can be re-analyzed from the Impedance tab.

Co-authored-by: Cursor <cursoragent@cursor.com>
This commit is contained in:
2026-09-11 00:21:49 +02:00
co-authored by Cursor
parent 796cd9d8a2
commit 3f6082ae6d
12 changed files with 731 additions and 22 deletions
+1 -1
View File
@@ -106,7 +106,7 @@ Passi:
| --- | --- | --- | --- |
| 1 Plugin / telemetry / BOM match | Parser KiCad XML/sexp/`.kicad_sch` gerarchico; wizard BOM; `plugins/kicad/` + cad-bridge JSON | EasyEDA fuori scope; uuid/sheet sul plugin da verificare su board reale | **OK** |
| 2 Datasheet / errata / OCR blocchi | Pintable, excerpt, quote_verify, errata, `internal_features` | Nessun RAG vendor | **OK** |
| 3 Impedenze / stackup | ImpedenceFinder + tab Impedance + `.kicad_dru` | CPWG non nel vendor; niente Z0 sul rame del PCB | **OK** |
| 3 Impedenze / stackup | ImpedenceFinder: calcolatrice + **Z0 sulle tracce** dei net signal (stackup PCB) | CPWG non nel vendor | **OK** |
| 4 Filtri | `check_filters` (solo con poli/numeri in specs) | Niente \(f_c\) inventata | **OK** |
| 5 Capacità PI | Decoupling sulla net; derating V; DC-bias/ESR se c’è il numero; mm sul PCB (`PS-PLC-001`) | — | **OK** |
| 6 Elettrico | Pin mux; I2C/reset pull-up; LED; sequencing/IR/power margin se c’è il parametro | Senza numero in specs → skip | **OK** |